What do EN 13541, ISO 16933, ISO 16934 and GSA mean for blast glazing?

Lesson 13 of 20 · about one minute

EN 13541 rates glass ER1 to ER4 in a shock tube, with S or NS. EN 13123/13124 cover windows and doors in shock tube or arena tests. ISO 16934 (shock tube) and ISO 16933 (open-air arena) give glazing a hazard rating from A (no break) to F (high hazard). GSA and ASTM F1642 are US methods. A hazard rating only applies at the blast load it was tested at.

Written by Josh Astin, Commercial Director, British Aluminium · Last reviewed 27 November 2026 · Lesson 13 of 20

The main standards

  • EN 13541: glass in a shock tube, ER1 to ER4, S or NS.
  • EN 13123 / EN 13124: windows and doors, shock tube or arena tests.
  • ISO 16934: glazing in a shock tube, with a hazard rating.
  • ISO 16933: glazing in an open-air arena blast, with a hazard rating.
  • GSA / ASTM F1642: US methods, rated from no break to high hazard.

Hazard ratings (ISO)

  • A: no break
  • B: no hazard
  • C: minimal hazard
  • D: very low hazard
  • E: low hazard
  • F: high hazard

Key facts

Glass (EU)EN 13541 – ER1 to ER4
Windows and doors (EU)EN 13123 / EN 13124
Glazing (ISO)ISO 16933 arena, ISO 16934 shock tube
USGSA, ASTM F1642
Hazard scaleA (no break) to F (high hazard)

Questions architects ask

Shock tube or arena: which is better?

Both are valid. A shock tube is repeatable; an arena uses a real charge.

Can I compare two hazard ratings?

Only at the same blast load.

What should I ask for?

The test standard, the load and the hazard rating for the whole system.

Related

About British Aluminium

British Aluminium designs and manufactures fire-rated, bullet-resistant, blast-resistant and anti-attack glazing, doors and windows in aluminium and steel. Made in the GCC, for projects in Qatar, Saudi Arabia, Oman and export markets. BA Academy is our series of short lessons for architects, consultants and contractors on fire, bullet and blast glazing.