But film on its own is not a blast system. What turns it into one is the anchoring that holds the filmed glass into the frame.
But film on its own is not a blast system. What turns it into one is the anchoring that holds the filmed glass into the frame. Almost every disappointment with film comes from specifying the first half and forgetting the second.
What film actually does
A safety and security film is a multi-layered polyester laminate bonded to the room side of the glass with a pressure-sensitive adhesive. It does not stop the glass breaking. It holds the broken pieces to itself so they do not become projectiles.
- Anti-fragmentation. The primary function. Glass fragments stay adhered to the membrane rather than flying into the occupied space.
- Blast mitigation. The film stretches and absorbs a proportion of the shock energy before tearing, and — when anchored — keeps the pane in the opening.
- Forced-entry delay. The glass breaks, but the opening does not, delaying an intruder.
- Spontaneous breakage containment. Particularly relevant for toughened glass at height, where nickel sulphide inclusions can cause failure with no warning.
- Solar control and UV rejection, where a combined film is specified.
Film is measured in microns or mils — 1 mil = 25 micron. Typical architectural grades run from 100 micron (4 mil) safety film through to 375 micron (15 mil). For blast mitigation, 200 micron (8 mil) is the usual starting point, and UK protective security guidance has long treated 100 micron as the minimum for any blast-mitigation purpose.
The half everyone forgets — anchoring
Unanchored film holds the glass together but does not hold it in the frame. Under blast the whole filmed pane can be pushed into the room, or drawn out of the opening during the negative phase, as a single heavy sheet. Anchoring bonds the film to the frame so the assembly acts as one.
What the test data actually says
Blast performance belongs to the combination of a named film, a named attachment and a specific glass make-up — never to the film alone. The table below is published data for 3M Scotchshield Ultra S800, a 200 micron (8 mil) micro-layered film, tested to GSA-TS01-2003 and ASTM F1642.
What film cannot do
Applied film is not a ballistic product. No thickness of polyester film makes glass bullet-resistant, and no film carries an EN 1063, EN 1522 or UL 752 classification. Ballistic protection requires a laminated glass or glass-clad polycarbonate build-up in a tested frame. Film reduces the fragment hazard around a ballistic event; it does not stop the round.
- It does not make the frame stronger. If the existing frame or its anchorage cannot carry the blast reaction, film and anchoring will not change that.
- It does not fix a failed insulating unit. Film goes on the inner pane; the outer pane of an IGU is unprotected and will still be lost.
- It has a service life. Adhesive and polyester degrade under UV and heat, and Gulf exposure is severe. Manufacturers warrant flat-glass interior applications for a defined period; older installations should be assessed rather than assumed.
- It does not survive being cleaned wrongly. Abrasive or strongly acidic and alkaline cleaners damage the surface. Cleaning regimes need to be handed over with the building.
Film or new glazing
On most existing buildings the honest answer is that film with proper anchoring delivers a large proportion of the available benefit for a small proportion of the cost and disruption. It is rarely the highest-performing option, and it is very often the right one.
What we supply
- Frame survey and feasibility. We establish what attachment the existing frames will actually accept before anything is quoted.
- Film and anchoring supply and installation, including wet glaze, bonded and mechanical profiles and cable arrest systems.
- Test evidence for the combination supplied — film, attachment and glass — not a product datasheet on its own.
- Integration with our certified systems. Where film cannot reach the requirement, we can quote the replacement blast, ballistic or fire-rated system alongside it, so the comparison is on one page.
The range at British Aluminium
We supply the complete range across both certification systems — EN and US — as certified assemblies, not assembled from separately rated parts.
Issued for information. Product data is reproduced from the manufacturers' published technical literature and is subject to their own terms; performance for any specific installation is established by test data for that combination of film, attachment and glass. Selection of the design threat and the required hazard rating is the responsibility of the project's security consultant and the authority having jurisdiction. Standards are cited as at the date shown and this guide is revised without notice; always work from the current issue.
The full guide
This page gives the text of our technical guide. The tables, charts and quick-reference sheet are in the PDF: download the full guide.
Related
Have a project requirement?
Send your drawings, specification and project location. Tell us what the opening needs to achieve and where you need support.