What does UL 263 / ASTM E119 mean for glazing?
BA Academy lesson · about five minutes
UL 263 and ASTM E119 are the US fire tests for walls, floors and other building elements. Glazing that passes them is fire-resistive: it stops flames and keeps the protected side cool, with an average temperature rise below 250 °F (139 °C). It is treated as a transparent wall rather than an opening, so with matching rated framing it is not held to the 25 percent area limit or the 100 square inch door limit.
By Josh Astin, British Aluminium · Updated 27 November 2026
Where it is used
Glazed walls in stair and lift cores, corridors that form part of escape routes, large vision panels in fire doors, and anywhere people may be close to the glass during a fire. Ratings usually run from 60 to 120 minutes. The label carries W and the minutes, for example W-60.
The frame matters
The listing covers a specific glass and frame together. Fire-resistive glass in a fire-protective frame does not make a fire-resistive assembly.
What to ask the bidder
- Is the assembly listed to UL 263 or ASTM E119, frame included?
- Is the label marked W with the minutes required?
- Do the sizes fit within the listing?
Questions people ask
Is UL 263 the same as EN EI?
Both limit heat, but they are different tests. Use the one the project specifies.
Can fire-resistive glass be bullet or blast resistant too?
Yes, some build-ups are, if each rating has its own evidence.
Related
About British Aluminium
British Aluminium designs and manufactures fire-rated, bullet-resistant, blast-resistant and anti-attack glazing, doors and windows in aluminium and steel. Made in the GCC, for projects in Qatar, Saudi Arabia, Oman and export markets. BA Academy is our series of short lessons for architects, consultants, contractors and procurement teams.
BA products for this
British Aluminium systems where this topic applies.
Comparing offers on a live tender?
Send the specification and the offers you have received. We will tell you which tested systems match the requirement.