US fire ratings: UL, NFPA and the IBC
7 short lessons with quick answers
The US system used across Saudi Arabia and much of the GCC: fire-protective vs fire-resistive glazing, UL 9, UL 10C, UL 263, glazing markings and NFPA 80.
What this guide covers
- Tell fire-protective from fire-resistive glazing
- Explain UL 9, UL 10C and UL 263 and what each covers
- Read a fire-rated glazing marking such as D-H-NT-90
- Explain what NFPA 80 requires on site and after handover
Lessons
- 1Fire-protective or fire-resistive glazing: what is the difference?
- 2What do UL 9 and NFPA 257 test?
- 3What is UL 10C, and why does positive pressure matter?
- 4What does UL 263 / ASTM E119 mean for glazing?
- 5How do you read the marking on fire-rated glass (D-H-NT-90, W-60, OH-45)?
- 6What does NFPA 80 require for fire doors and windows?
- 7Can a UL fire test report satisfy an EN specification?
Quick answers
What is fire-protective glazing?
Glazing tested to UL 9, UL 10B/10C or NFPA 252/257 that stops flames and smoke but not radiant heat, so the code limits its size and use.
What is fire-resistive glazing tested to?
ASTM E119 or UL 263, the same tests used for walls. It limits heat transfer as well as flames.
How much of a wall can fire-protective glazing cover?
Fire windows with fire-protective glazing are generally limited to 25 percent of the wall area, because radiant heat passes through.
How big can a fire-protective vision panel in a fire door be?
In fire doors serving exit stairs and passageways, 100 square inches (0.065 m²). Larger panels need fire-resistive glazing tested with the door.
What is the difference between UL 10B and UL 10C?
UL 10C runs the furnace at positive pressure, pushing hot gases through the gaps to test seals and hardware. The IBC requires it for swinging fire doors.
What does "W" mean on fire-rated glass?
It meets wall assembly criteria: tested to ASTM E119 or UL 263, so it is fire-resistive.
What does "NH" mean on fire-rated glass?
The glazing did not meet the hose stream test. "H" means it did.
What does "OH-45" mean on fire-rated glass?
It meets fire window assembly criteria (UL 9 or NFPA 257) including the hose stream, with a 45-minute rating.
Is NFPA 80 a fire test?
No. NFPA 80 is the standard for installing, inspecting and maintaining fire doors, fire windows and other opening protectives.
How often must fire doors be inspected under NFPA 80?
At least once a year, with every fire door assembly inspected and tested.
Other BA Academy guides
How fire-rated glass, frames and doors work, how they are tested in Europe, and why the rating belongs to the whole assembly.
How the Saudi Building Code, Civil Defense, SASO and Saudi Aramco shape what you can specify and install for fire-rated and security openings.
The three rating systems you will meet in GCC security specifications, what each level means, how they compare, and how to specify a complete bullet-resistant opening.
What happens to a window in an explosion, how blast glazing is rated, and what a blast specification and offer must contain.
For procurement, quantity surveyors and contractors: how to check that fire, bullet and blast offers answer the same requirement before comparing prices.
About British Aluminium
British Aluminium designs and manufactures fire-rated, bullet-resistant, blast-resistant and anti-attack glazing, doors and windows in aluminium and steel. Made in the GCC, for projects in Qatar, Saudi Arabia, Oman and export markets. BA Academy is our series of short lessons for architects, consultants, contractors and procurement teams.
Comparing offers on a live tender?
Send the specification and the offers you have received. We will tell you which tested systems match the requirement.